1.
Radiol. bras ; 48(1): 26-32, Jan-Feb/2015. tab, graf
Article in English | LILACS | ID: lil-741690

ABSTRACT

Objective: The present study was aimed at evaluating the viability of replacing 18F with 99mTc in dose calibrator linearity testing. Materials and Methods: The test was performed with sources of 99mTc (62 GBq) and 18F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical 99mTc and 18F sources activities were calculated and subsequently compared. Results: Mean deviations between experimental and theoretical 99mTc and 18F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the 99mTc source as measured with the equipment pre-calibrated to measure 99mTc and 18F was 3.42 (± 0.06), and for the 18F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion: The results of the linearity test using 99mTc were compatible with those obtained with the 18F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in 18F acquisition suggest 99mTc as the element of choice to perform dose calibrator linearity tests in centers that use 18F, without any detriment to the procedure as well as to the quality of the nuclear medicine service. .


Objetivo: Avaliar a viabilidade de substituir o radioisótopo 18F pelo 99mTc no teste de linearidade em medidores de atividade. Materiais e Métodos: O teste foi realizado empregando-se fontes de 99mTc (62 GBq) e 18F (12 GBq), cujas atividades foram mensuradas até valores abaixo de 1 MBq. As razões e desvios entre as atividades experimentais e teóricas foram calculados e comparados. Resultados: Os desvios médios entre as atividades experimentais e teóricas para o 99mTc e 18F foram, respectivamente, 0,56 (± 1,79)% e 0,92 (± 1,19)%. A razão média entre as atividades indicadas pelo equipamento para a fonte de 99mTc quando mensurada no equipamento pré-ajustado para medir o 99mTc e 18F foi 3,42 (± 0,06), e para o 18F este valor foi 3,39 (± 0,05), razões consideradas constantes ao longo de todo o período de medida. Conclusão: Os resultados do teste utilizando o 99mTc são compatíveis com os adquiridos com o 18F, implicando na possibilidade de utilização de ambos os radioisótopos na realização do teste de linearidade. Esta informação, aliada ao elevado potencial de exposição e custos de aquisição do 18F, sugere que o 99mTc seja empregado na realização do teste de linearidade para clínicas que utilizam 18F, sem prejuízo para o procedimento e garantia da qualidade de um serviço de medicina nuclear. .

2.
Arq. bras. cardiol ; 103(5): 375-381, 11/2014. tab
Article in English | LILACS | ID: lil-730360

ABSTRACT

Background: Appropriateness Criteria for nuclear imaging exams were created by American College of Cardiology (ACC) e American Society of Nuclear Cardiology (ASNC) to allow the rational use of tests. Little is known whether these criteria have been followed in clinical practice. Objective: To evaluate whether the medical applications of myocardial perfusion scintigraphy (MPS) in a private nuclear medicine service of a tertiary cardiology hospital were suitable to the criteria of indications proposed by the American medical societies in 2005 and 2009 and compare the level of indication of both. Methods: We included records of 383 patients that underwent MPS, November 2008 up to February 2009. Demographic characteristics, patient's origin, coronary risk factors, time of medical graduation and appropriateness criteria of medical applications were studied. The criteria were evaluated by two independent physicians and, in doubtful cases, defined by a medical expert in MPS. Results: Mean age was 65 ± 12 years. Of the 367 records reviewed, 236 (64.3%) studies were performed in men and 75 (20.4%) were internee. To ACC 2005, 255 (69.5%) were considered appropriate indication and 13 (3.5%) inappropriate. With ACC 2009, 249 (67.8%) were considered appropriate indications and 13 (5.2%) inappropriate. Conclusions: We observed a high rate of adequacy of medical indications for MPS. Compared to the 2005 version, 2009 did not change the results. .


Fundamento: Os critérios de adequação para os exames de imagem nuclear foram criados pelo American College of Cardiology (ACC) e pela American Society of Nuclear Cardiology (ASNC) com o objetivo de permitir o uso racional dos exames. Pouco se sabe se esses critérios têm sido seguidos nas indicações da prática clínica. Objetivo: Avaliar se os pedidos médicos de cintilografia de perfusão miocárdica (CPM), em serviço privado de medicina nuclear de um hospital cardiológico terciário, adequavam-se aos critérios de indicações propostos pelas sociedades médicas americanas em 2005 e 2009 e comparar o grau de indicação entre ambos. Métodos: Foram incluídos 383 prontuários de pacientes submetidos à CPM de novembro de 2008 a fevereiro de 2009. As características demográficas, a origem do paciente, os fatores de risco coronariano, o tempo de formatura do médico e os critérios de adequação dos pedidos foram considerados. Os critérios foram avaliados por dois médicos independentes e, nos casos duvidosos, definidos por um especialista em CPM. Resultados: A média de idade foi de 65 ± 12 anos. Dos 367 prontuários analisados, 236 (64,3%) exames foram realizados em homens e 75 (20,4%) foram em pacientes internados. Aplicando-se os critérios do ACC de 2005, 255 (69,5%) das indicações foram consideradas adequadas e 13 (3,5%) inadequadas. Aplicando-se os critérios do ACC de 2009, 249 (67,8%) das indicações foram consideradas adequadas e 13 (5,2%) inadequadas. Conclusões: Foi observada uma elevada taxa de adequação das indicações médicas de CPM. Comparada com a edição de 2005, a versão de 2009 não alterou a taxa de exames adequados ou inadequados. .

3.
Arq. bras. endocrinol. metab ; 53(3): 318-325, Apr. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-517674

ABSTRACT

OBJETIVO: Determinar exposições decorrentes da radioiodoterapia ambulatorial do carcinoma diferenciado da tireoide (CDT) sobre os familiares dos pacientes e o meio ambiente. MÉTODOS: Administraram-se 100 a 150 mCi de (131I)NaI para tratamento ambulatorial de 20 pacientes com CDT. Monitorizaram-se com dosímetros termoluminescentes as doses de radiação recebidas por familiares (n = 27) e potenciais de dose nas residências. Também foram monitorizadas contaminação de superfície e rejeitos radioativos. RESULTADOS: Registraram-se doses < 1,0 mSv em 26 acompanhantes e 2,8 mSv em um caso, inferiores ao aceitável para exposições médicas (5,0 mSv/procedimento). Excetuando-se o quarto dos pacientes (média = 0,69 mSv), determinou-se potencial de dose nas residências < 0,25 mSv. A contaminação de superfícies (4,2 Bq.cm-2) não ultrapassou níveis de liberação, sem representar riscos mesmo em simulações do pior cenário. Os rejeitos radioativos tiveram volume de 2,5 litros e atividade estimada em 90 µCi (média = 4,5 µCi/paciente). CONCLUSÕES: Não foi constatado impacto radiológico ao meio ambiente ou aos familiares de pacientes tratados ambulatorialmente com 100 a 150 mCi de iodo-131 e acompanhados por profissionais qualificados.


PURPOSE:To evaluate exposure and dosimetry to family members and environment due to outpatient radioiodine therapy of differentiated thyroid carcinoma. METHODS: Twenty patients were treated with 100-150mCi of iodine-131 on an out-patient basis. Family members dosimetry (n = 27) and potential doses inside the house were measured with thermoluminescent dosimeters. Surface contamination and radioactive wastes were also monitored. RESULTS: Less than 1.0 mSv doses were found in 26 co-habitants and 2.8 mSv in a single case (inferior to the acceptable value of 5.0 mSv/procedure). Potential doses in the houses were inferior to 0.25 mSv, excluding the patients bedroom (mean value = 0.69 mSv). Surface contamination (mean = 4.2 Bq.cm-2) were below clearance levels. Radioactive wastes generated had a volume of 2.5 liters and a total activity estimated in 90 µCi, with a calculated exposure close to the background radiation levels. CONCLUSIONS: No radiological impact was detected after iodine therapy with 100-150 mCi on an out-patient basis followed by experienced professionals.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Environmental Exposure/prevention & control , Family , Iodine Radioisotopes/administration & dosage , Radiation Protection/methods , Thyroid Neoplasms/radiotherapy , Ambulatory Care , Iodine Radioisotopes/adverse effects , Radiotherapy Dosage , Radiation Protection/standards , Thermoluminescent Dosimetry , Thyroidectomy , Thyroid Neoplasms/surgery